Configuring the 7400b for remote administration, Restoring factory defaults for the 7400b – Avaya 555-233-116 User Manual

Page 79

Advertising
background image

Connect data modules

Issue 4 October 2002

79

555-233-116

The 7400B data module can be used at a remote site as a dedicated service
device to answer incoming data calls, send data to a remote end device, and then
hang up. For example, you might wish to provide access to a printer from a
remote site. The following is a typical command line you might use for setting up
this operation (spaces are used here for readability, but are not required):

1. at &c1 &d2 q1 s0=1 &w0 &y0

where:

at puts the modem in command mode

&C1 sets the Data Carrier Detect (DCD) circuit of the data module to
operate according to the EIA standard

&D2 sets the data module to go on hook when an on-to-off transition
is detected on the Data Terminal Ready (DTR) input, disconnecting
the call

Q1 turns off the result codes that would be the normal responses of
the data module to commands that it receives.

S0=1 turns on the automatic answer feature and causes the data
module to answer an incoming data call on the first ring

&W0 causes the current configuration to be stored in profile 0

&Y0 selects the configuration stored in profile 0 to become the
current configuration each time the data module is powered on

Configuring the 7400B for remote administration

1. At the command prompt of your terminal-emulation software or terminal,

enter at&c1&d2&s1s0=1&w0&w1&y0

where:

at puts the modem in command mode

&c1 tells the modem to respond to DCD

&d2 tells the modem to respond to DTR

&s1 tells the modem to respond to DSR

s0=1 tells the modem to auto answer on the first ring

&w0 tells the modem to save changes in profile 0

&w1 tells the modem to save changes in profile 1

&y0 tells the modem to use profile0 after a power failure

Restoring factory defaults for the 7400B

1. Enter at&F

Advertising