Administration, Partner installation – Avaya 555-233-116 User Manual

Page 181

Advertising
background image

DEFINITY INADS

Issue 4 October 2002

181

555-233-116

Administration

NOTE:

Add 2 pauses in front of the dial string when using cut-through trunks.
Pauses are not required if using ARS.

1. Type change system-parameters maintenance and press

Enter

.

2. For high reliability systems, in the

see interchange:

field, type daily

and press

Enter

. This is done in case 1 of the connections between the 2

TN1648B circuit packs is down. This assures that within 24 hours the
working connection is available to report alarms.

3. Type add station number or next and press

Enter

.

4. In the

Type

field, enter 500 (rotary analog telephone).

5. In the

Port

field, enter the port number for this line.

6. For high reliability systems, repeat the above steps for the second analog

line. Administer the 2 stations as part of a TEG (terminating extension
group).

a. Type add term-ext-group number or next and press

Enter

.

b. In the

Group Extension

field, enter the TEG extension number.

c. In the

Coverage Path

field, enter the coverage path number.

d. Enter the Group Member Assignment station numbers.

e. Press

Enter

when finished.

Partner installation

The PARTNER system connects the INADS port to an outgoing central office
(CO) line and is programmed to seize the outside line when INADS seizes an
inside PARTNER station line.

There are 2 types of PARTNER platforms:

PARTNER Atlas platforms with U.S. firmware and a wide input power
supply (WIPS) that allows a universal power supply. The Spain platform
conforms to the United States/Atlas platform

European platforms that focus on eastern Europe and the United Kingdom

The installation procedure describes the 2 types of PARTNER platforms with or
without power fail transfer.

Advertising