Data modules and asynchronous data units

555-233-116

66

Issue 4 October 2002

2. If you pressed the ENTER/YES button at the SET LeadName LEAD?

prompt, the LeadName -> ON? prompt appears. Press the ENTER/YES
button.

3. Repeat until all leads have been set.

Setting parity on 7400A DCE

Next you need to identify the type of parity coding that the data module should
expect. Parity is an error-detection scheme that is based on the value of a parity
bit in each unit of information. Four coding schemes are used: ODD, EVEN,
MARK, and SPACE. In odd-parity coding, the parity bit is set to 0 if the number of
1s in the information is odd, 1 if it is even. In even-parity coding, the parity bit is
set to 0 if the number of 1s in the information is even, 1 if it is odd. Mark-parity
coding always sets the parity bit to 1. Space-parity coding always sets the parity
bit to 0.

1. Accept the default value, unless otherwise instructed. When the SET

PARITY? prompt appears, press the NEXT/NO button to keep the default,
SPACE.

Enabling remote loopback testing on 7400A DCE

You can set the remote loopback option to GRANT

or DENY.

1. Accept the default value, unless otherwise instructed. When the SET

REMOTE LOOP? prompt appears, press the NEXT/NO button to keep the
default, GRANT

.

LeadName -> ON?

DATA

NEXT/NO

BACK

ENTER/YES

➜ ●

Push the button indicated by the arrow (

)

SET PARITY?

DATA

NEXT/NO

BACK

ENTER/YES

➜ ●

Push the button indicated by the arrow (

)

SET REMOTE LOOP?

DATA

NEXT/NO

BACK

ENTER/YES

➜ ●

Push the button indicated by the arrow (

)