Configuring the expressroute 1000 data module – Avaya 555-233-116 User Manual

Page 94

Advertising
background image

Data modules and asynchronous data units

555-233-116

94

Issue 4 October 2002

Proceed as follows.

1. Calculate an option-selection value using

Table 12

,

‘‘Codes for disabling

default settings of the 8400B data module’’

. Add up the disabling codes for

all options that you wish to disable.

For example, if you turned off With Telephone, US Companding, Disable
Data Metering Feature
, the selection code would be:

1 + 2 + 16 = 19

2. Check the current data-module setting by entering ATS24?.

3. If the current value does not match the selection value you calculated,

enter ATS24=nnn, where nnn is the selection value you calculated.

Configuring the ExpressRoute 1000 data module

You can substitute an ExpressRoute 1000 data module for the 8400B data
module. Both DCP and ISDN-BRI connections are possible.

Figure 18

shows

typical connections.

!

CAUTION:

In DC-powered cabinet installations, a 105C Isolator adapter is required
when connecting equipment to a data module.

Disable Data Metering Feature

16

Immediate Speakerphone Activation

32

Automatic Speakerphone Activation

64

Disable Busyout During Local Loopback Test

128

Table 12.

Codes for disabling default settings of the 8400B data module

Default setting

Disabling code

Continued on next page