Checking definity administration on 7400a dce – Avaya 555-233-116 User Manual

Page 69

Advertising
background image

Connect data modules

Issue 4 October 2002

69

555-233-116

You return HOME.

Checking DEFINITY administration on 7400A DCE

Check that the DEFINITY is administered to support the 7400A data module in the
DCE application as follows:

1. If necessary, return to the HOME display on the 7400A by pressing the

NEXT/NO and BACK buttons at the same time.

2. From the HOME display, press NEXT/NO until ANS/ORIG CALL?

is

displayed, then press the ENTER/YES button.

3. If you see the message WAITING ... DISCONNECTED, the switch has not

been administered correctly.

4. If you see the message DIAL TONE followed by DISCONNECT CALL?,

the DEFINITY is correctly administered for the 7400A data module. Press
the ENTER/YES button to return to the menu.

The 7400A replies WAITING ... DISCONNECTED and returns to the ANS/
ORIG CALL?
menu.

5. Return to the HOME display by pressing the NEXT/NO and BACK buttons

at the same time.

Configuring the 7400A for modem pooling (DTE) applications

From the HOME screen, proceed as follows.