Data modules and asynchronous data units

555-233-116

96

Issue 4 October 2002

Screen 1.

Typical system-configuration listing

2. Locate an unassigned port on a suitable circuit pack, and make a note of

the corresponding port number.

The port number is the Board Number, UUCSS (where UU is the 2-digit
cabinet number, C is the single-character carrier identifier, and SS is the 2-
digit slot number) followed by the next 2-digit number, PP, in the sequence
in the Assigned Ports fields at the right side of the form: UUCSSPP.

For example, in the listing above, the next available port address for the
TN2181 digital line circuit pack would be 01A0503.

3. From the DEFINITY administration console, open a new data-module form

by typing

add data-module next

The system automatically assigns the next available extension number to
the data module.