Standard reliability – Avaya 555-233-116 User Manual

Page 183

Advertising
background image

DEFINITY INADS

Issue 4 October 2002

183

555-233-116

Figure 42.

INADS connection (European platform)

Standard reliability

Normal connection: Connect the INADS tip and ring port from the AUX
connector (wire pair 50 and 25) to the tip/ring pair of CO line port 1 on the
PARTNER system.

US/Atlas/Spain platform connection: Connect station 10 to the INADS
port.

European platform connection: Bridge the outside pair of CO line port 1
to the INADS port. A 258A adapter may be used.

1. PARTNER System
2. MLS12D telephone for programming
3. Standard RJ-45 telephone cord
4. 103A or modular wall jack
5. Pins 2,3 on cable 5 bridge to pins 1,4

of cable 7 inside MDF

6. Dial tone from the CO or extension on

pins 2,3; with return dial tone to the
INADS port on pins 1,4 during power
failure

7. Main distribution frame (MDF)
8. PSTN or switch extension
9. B25A 25-pair cable to AUX

10. AUX connector (use wire pair 50,25, tip and

ring)

11. Avaya Media Server or Gateway PPN

12. Standard RJ-45 connector (pins 2,3, tip and

ring, connect to pins 1,4, tip and ring, when
the internal contacts close during power
failure)