29

measuring.

3-2. The second row in SETUP section:

ESC: Cancels selection, moving back to measurement display.

ENTER: Accepts selection, moving to next choice or back to

measurement display.

LOCK: Presses SHIFT then ESC button to prevent unpredictable

operation on the panel. In order to release lock condition, please

press ESC again.

3-3. The third row in SETUP section:

CONFIG: Offers setting or adjusting function, relating some front

panel buttons.

MENU: Offers setting or adjusting function, not relating other front

panel buttons.

4. RANGE:

△: Moves to higher range.

▽: Moves to lower range.

AUTO: Enables or disables auto-range.

5. Terminals: Selects input signal connections on front or rear panel.

6. Inserted Connections & Fuse Device:

4 Chassis Ground Connections: Separate environmental noises.



HI

& LO: Used for all measurements, except DC and AC current.

(Maximum input voltage: 1000V for voltage measurements. 200V for

4-wire measurement)

LO &

I

: Used for making DC and AC current measurements.

Front Fuse: Secures your Meter against damage of strong current pulse.

(Maximum current: 3A, 250V)

7. Chassis Ground Terminal:



The chassis ground terminal is used for shielding the noise from the

nature, especially when users want to get a very small signal via the

application of a BNC-to-Banana Adapter. Please refer to the Figure

2-16.