II - 1 Installation Set

u

p

To measure the standard using an edge finder, touch one end of the
block. The Measured Field shows 0. Move to the second edge, and
touch the other end of the gauge block. The measured size, plus any
tool offset appears in the field.

To measure the standard using a tool, touch one end of the block, and
press teach. The Measured Field shows 0. Move to the second edge,
and touch the other end of the gauge block. Press TEACH. The
measured size, plus any tool offset appears in the field.

The Factor Field shows the calculated correction factor based on the
measured and standard value.

Press the ENTER key to exit the form and update the table with
information on the new interval, or C to exit without transferring
the factor. A compensation table may also be imported, or the new
table can be exported.

Exporting the current Compensation Table

8

Press the IMPORT/EXPORT soft key.

8

Press the EXPORT soft key.

Importing a new Tool Table

8

Press the IMPORT/EXPORT soft key.

8

Press the IMPORT soft key.