Ii - 6 error messages, Ii - 6 er ro r messag es ii - 6 error messages – ACU-RITE 300S READOUTS User Manual

Page 115

Advertising
background image

300S

101

II - 6 Er

ro

r Messag

es

II - 6 Error Messages

The following table provides a complete list of error messages that
may be received from the 300S DRO.

An explanation of each error message is provided in the following
table.

Error

DRO Error Message

Explanation

1

Power was off. Press any key to
continue.

300S power was just cycled.

2

Contamination & Frequency Error:
Press C to clear error.

Contamination, and frequency errors occurred at corresponding encoder.
User intervention to monitor, and/or correct the encoder.

3

Contamination Error: Press C to
clear error.

Contamination error occurred at corresponding encoder. User intervention to

monitor, and/or correct the encoder.

4

Frequency error: Press C to clear
error.

Frequency error occurred at corresponding encoder. User intervention to
monitor, and/or correct the encoder.

5

Miscount error: Press C to clear
error.

Miscount error occurred at corresponding encoder. User intervention to
monitor, and/or correct the encoder.

6

Display Overflow error: Move
within display range.

The encoder is currently out of the display range specified by the user. Move
the encoder to within the display range, or modify the encoder display.

7

Error: The valid range for number of
holes is 1-99.

The number of holes defined for the current pattern is out of range. User must
adjust the number of holes.

8

Error: The radius must be greater
than 0.0.

The user defined radius must be greater than zero to define a circle.

9

Error: The spacing must be greater
than 0.0.

The spacing between holes in a pattern must be greater than zero to define a
pattern.

10

Error: The start and end points can
not be the same.

The start, and end points of the field must be unique to define a line.

11

Error: The distance from the center
is not equal to the radius.

The distance from the center value is invalid, and must be modified by the
user.

12

Error: The ARCCOS function can
only operate on values from - 1to 1.

Range error on the value to fetch the arccos of.

Advertising