Ii - 6 er ro r messag e s – ACU-RITE 300S READOUTS User Manual

Page 116

Advertising
background image

102

II

II - 6 Er

ro

r Messag

e

s

Error

DRO Error Message

Explanation

13

Error: The ARCSIN function can only
operate on values from - 1to 1.

Range error on the value to fetch the arcsin of.

14

Error: The TAN function is undefined
at 90, and -90 degrees.

Range error on the value to fetch the tangent of.

15

Error: The square root of a negative
number is undefined.

Can not take the square root of a negative number.

16

Error: Divide by zero error.

Can not divide by zero.

17

Unable to transfer configuration
parameters. The external device is
not ready.

The external device hooked to the serial port is not working. Check the

physical connection, and verify that the serial communications parameters are
correct.

18

Error: One or more of the
configuration parameters was invalid,
and could not be loaded.

The configuration file being imported is corrupt. Import file again. If error
persists, import a different configuration file.

19

Error: Parameter was invalid. It has
been set to it’s previous value.

An invalid configuration parameter was discovered on import, and was reset
to the previous value. Check the configuration file that failed, and import
again.

20

Error: The valid range for scale factor
is -10 to -0.1, and 0.1 to 10.

The current scale factor value is out of range. Adjust the scale factor value to
reflect a valid number.

21

Error: At least one axis must be
selected for DRO 1.

When defining multiple DRO, and corresponding views, user must define at
least one axis for the default DRO 1.

22

Error: The valid range for the error
correction factor in parts per million is
-99999 to +99999.

Out of range for the error correction factor defined within error compensation.
When defining the error correction factor, the user must use the correct
range.

23

A program with this name already
exist. Proceed?

A program using the current name already exists, and will be written over the
existing program. Proceed, or cancel current operation.

24

Program Import Failed.

The user selected program was not imported successfully. Check physical
serial connection. Check validity of file. Import again.

25

Error: No current program to clear.

No program to clear is currently selected. Select a program using the
UP/DOWN arrow keys.

26

Error: No program to load.

No program is currently selected to load. Select a program using the
UP/DOWN arrow keys.