I

I - 4 T

u

rn

ing Specific Oper

ations

Enabling Z

0

, and Z Coupling

To couple the Z

0

, and Z axes and have the result displayed on the Z

0

display, press and hold the Z

0

key approximately 2 seconds. The sum

of the Z positions will be displayed on the Z

0

display and the Z display

will be blanked.

To couple the Z

0

, and Z axes and have the result displayed on the Z

display, press and hold the Z key for approximately 2 seconds. The
sum of the Z positions will be displayed on the Z display and the Z

0

display will be blanked. The coupling is preserved in between
power cycles.

Moving either Z

0

, or Z inputs will update the coupled Z position.

When a position is coupled, the reference mark for both encoders
must be found in order to recall the previous datum.

Disabling Z

0

, and Z Coupling

To disable Z Coupling, press the axis key of the display that is blank.
The individual Z

0

, and Z display positions will be restored.