Gold Solo Hornet Installation Guide (EtherCAT and CAN)

Product Description

MAN-G-SOLHORIG-EC (Ver. 1.009)

|

www.elmomc.com

16

Table of Contents

2.2.10. Safety

IEC 61800-5-2, Safe Torque Off (STO)

Two STO (Safe Torque Off) inputs PLC level which can be configured to 5 V logic (available

on request)

Optically isolated

TTL Level (5 V logic)

Open collector and open emitter

UL 508C recognition

UL 60950 compliance

CE EMC compliance

2.2.11. Outputs

Two digital isolated output

2.2.12. Differential Outputs

Three differential outputs:

Port C EIA-422 differential output line transmitters

Response time < 1 μs

Output current: ± 15 mA.

2.2.13. Inputs

Six digital inputs – conforms to PLC Standard

TTL Level (5 V logic)

Optically isolated

Fast digital capture data <5 μs

The six digital inputs can be configured to TTL mode (available on request, see

Section 5.5.1)

2.2.14. Differential Inputs

Six very fast differential event capture inputs 5 V logic

Via Port A or B (three on each port, depending on model)

EIA-422 Differential input line receiver

Response time < 1 μs

2.2.15. Analog Input

One Analog Input – up to 14-bit resolution

One Analog input: ±10 V