Auxiliary Power Supply (J2) (Optional)

Note:

The source of the Auxiliary Supply must be isolated.

Connect the VL+ and PR pins on the Gold Solo Hornet in the manner described in Section 4.3.2.1.

The Gold Solo Hornet Auxiliary Power is part of the J2 connector, see Section 4.3.2.2 for more
details.

Pin (J2)

Signal

Function

2

PR

Auxiliary Supply Return

1

VL+

Auxiliary Power Input

Pin Positions

Table 10: Auxiliary Supply Pins

Caution: Power from the Gold Solo Hornet to the motor must come from the
Main Supply and NOT from the Auxiliary Supply.

The backup functionality can be used for storing control parameters in case of power-outs,
providing maximum flexibility and backup capability when needed.
Connect the VL+ and PR terminal to the Auxiliary Connector.

Note for auxiliary supply connections:

The source of the Auxiliary Supply must be isolated.

For safety reasons, connect the return (common) of the auxiliary supply source to the

closest ground near the auxiliary supply source.

Connect the cable shield to the closest ground near the auxiliary supply source.

Before applying power, first verify the polarity of the connection.

A cable kit containing a cable that connects to the auxiliary supply connector (J2) is available,
see Section 2.2.19 for more details.