Safe torque off (sto), Sto input interfaces – ttl mode, Sto input interfaces – plc mode – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Solo Hornet User Manual

Page 86

Advertising
background image

Gold Solo Hornet Installation Guide (EtherCAT and CAN) Technical Specifications

MAN-G-SOLHORIG-EC (Ver. 1.009)

|

www.elmomc.com

86

Table of Contents

5.6. Safe Torque Off (STO)

The Gold Solo Hornet has two STO (Safe Torque Off) inputs.

5.6.1.

STO Input Interfaces – TTL Mode

Feature

Details

Type of input

Optically isolated

Input current for all inputs

Iin = 3.8 mA @ Vin = 5 V

High-level input voltage

2.4 V < Vin < 15 V, 5 V typical

Low-level input voltage

0 V < Vin < 0.8 V

Minimum pulse width

>3 ms

Figure 38: STO Input Schematic

5.6.2.

STO Input Interfaces – PLC Mode

Feature

Details

Type of input

Optically isolated

Input current for all inputs

Iin = 2 mA @ Vin = 12 V

High-level input voltage

12 V < Vin < 30 V

Low-level input voltage

0 V < Vin < 7 V

Minimum pulse width

>3 ms

Figure 39: STO Input Schematic

Advertising