Main and auxiliary power, Main power (j1) – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Solo Hornet User Manual

Page 38

Advertising
background image

Gold Solo Hornet Installation Guide (EtherCAT and CAN)

Installation

MAN-G-SOLHORIG-EC (Ver. 1.009)

|

www.elmomc.com

38

Table of Contents

4.7.2.

Main and Auxiliary Power

This section describes the Main and Auxiliary Power for power ratings 200V and 100V, and
provides details for the optional Backup (Auxiliary) Supply.

4.7.2.1.

Main Power (J1)

The Gold Solo Hornet Main Power is part of the J1 connector, see Section 4.3.2.1 for more
details.

Pin

Function

Cable

PE

Protective Earth

Power

PR

Power Return

Power

VP+

Positive Power Input

Power

Pin Positions

Table 9: Main Power and Motor Connections

Power to the Gold Solo Hornet is provided by a 12 to 195 VDC source.
Connect the DC power cable to the VP+ and PR terminals on the Main Power Connector.

Notes for connecting the DC power supply

The source of the 12 to 195 VDC power supply must be isolated.

For best immunity, it is highly recommended to use twisted and shielded cables for the DC

power supply. A 3-wire shielded cable should be used. The gauge is determined by the
actual current consumption of the motor.

Connect the cable shield to the closest ground connection near the power supply.

Connect the PE to the closest ground connection near the power supply.

Connect the PR to the closest ground connection near the power supply.

Before applying power, first verify the polarity of the connection.