Installation

The Gold Solo Hornet must be installed in a suitable environment and properly connected to its
voltage supplies and the motor.

4.1. Site Requirements

You can guarantee the safe operation of the Gold Solo Hornet by ensuring that it is installed in
an appropriate environment.

Feature

Value

Ambient operating temperature

-40 °C to +70 °C (-40 °F to 160 °F)

Maximum operating altitude

2,000 m (6562 feet)

Maximum non-condensing humidity 95%

Operating area atmosphere

No flammable gases or vapors permitted in area

Caution: The Gold Solo Hornet dissipates its heat by convection. The maximum
ambient operating temperature of 40 °C (104 °F) must not be exceeded.

4.2. Unpacking the Drive Components

Before you begin working with the Gold Solo Hornet, verify that you have all of its components,
as follows:

The Gold Solo Hornet servo drive

The Elmo Application Studio software and software manual

The Gold Solo Hornet is shipped in a cardboard box with Styrofoam protection.
To unpack the Gold Solo Hornet:

1.

Carefully remove the servo drive from the box and the Styrofoam.

2.

Check the drive to ensure that there is no visible damage to the instrument. If any damage

has occurred, report it immediately to the carrier that delivered your drive.

3.

To ensure that the Gold Solo Hornet you have unpacked is the appropriate type for your

requirements, locate the part number sticker on the side of the Gold Solo Hornet. It looks
like this:

Advertising