Chapter 3: installation, Before you begin, Site requirements – ElmoMC SimplIQ Digital Servo Drives-Solo Trombone Installation Guide User Manual

Page 16: Chapter 3, Installation

Advertising
background image

Solo Trombone Installation Guide

MAN-SOLTROIG (Ver. 1.203)

www.elmomc.com

16

Chapter 3:

Installation

Warning:
The Solo Trombone must be:

installed in a suitable environment and properly connected to its voltage

supplies and the motor.

mounted and confined within a metal enclosure.

3.1. Before You Begin

3.1.1.

Site Requirements

You can guarantee the safe operation of the Solo Trombone by ensuring that it is installed in an
appropriate environment.

Feature

Value

Ambient operating temperature

0 °C to 40 °C (32 °F to 104 °F)

Maximum operating altitude

2,000 m (6562 feet)

Maximum relative humidity

90% non-condensing

Operating area atmosphere

No flammable gases or vapors permitted in area

Models for extended environmental conditions are available.

Caution:
The Solo Trombone dissipates its heat by natural convection. The maximum
ambient operating temperature of 0 °C to 40 °C (32 °F to 104 °F) must not be
exceeded.