4.6.2.6.

Tachometer

*

Feature

Details

Tachometer format

Differential

Maximum operating differential voltage for TAC1+, TAC1-

±20 V

Maximum absolute differential input voltage for TAC1+, TAC1-

±25 V

Maximum operating differential voltage for TAC2+, TAC2-

±50 V

Maximum absolute differential input voltage for TAC2+, TAC2-

±60 V

Input resistance for TAC1+, TAC1-

46 kΩ

Input resistance for TAC2+, TAC2-

100 kΩ

Resolution

14 bit

* Only one Tachometer port can be used at a time (either TAC1+/TAC1- or TAC2+/TAC2-).
TAC1+/TAC1- is used in applications with having a Tachometer of less than 20 V.
TAC2+/TAC2- is used in applications with having a Tachometer of between 20 V and 50 V.

4.6.2.7.

Potentiometer

Feature

Details

Potentiometer Format

Single-ended

Operating Voltage Range

0 to 5 V supplied by the Solo Trombone

Potentiometer Resistance

100 Ω to 1 kΩ above this range, linearity is affected
detrimentally

Input Resistance

100 kΩ

Resolution

14 bit