B single-phase direct-to-mains connection topology – ElmoMC SimplIQ Digital Servo Drives-Solo Trombone Installation Guide User Manual
Page 23
Advertising
Solo Trombone Installation Guide
Installation
MAN-SOLTROIG (Ver. 1.203)
23
3.3.3.2.b
Single-Phase Direct-to-Mains Connection Topology
Figure 4: Non-Isolated Single-Phase Connection Topology
The Power Supply is connected directly to the Mains AC line.
Warning:
•
Do not connect VN- to PE. In a direct-to-mains connection the VN- must
not be connected to the PE. Connecting the VN- to the PE will cause
irreparable damage to the system.
•
Be careful and note that in a direct-to-mains connection, the Neutral point
is not the most negative voltage level. It is the mid-point level of the
rectified DC bus.