23

3.3.3.2.b

Single-Phase Direct-to-Mains Connection Topology

Figure 4: Non-Isolated Single-Phase Connection Topology

The Power Supply is connected directly to the Mains AC line.

Warning:

Do not connect VN- to PE. In a direct-to-mains connection the VN- must

not be connected to the PE. Connecting the VN- to the PE will cause
irreparable damage to the system.

Be careful and note that in a direct-to-mains connection, the Neutral point

is not the most negative voltage level. It is the mid-point level of the
rectified DC bus.