Auxiliary supply, Environmental conditions – ElmoMC SimplIQ Digital Servo Drives-Solo Trombone Installation Guide User Manual

Page 68

Advertising
background image

Solo Trombone Installation Guide

Technical Specifications

MAN-SOLTROIG (Ver. 1.203)

www.elmomc.com

68

4.3.1.

Auxiliary Supply

This table applies only to the models with an S suffix. See page 17 for further details on the part
number.

Feature

Details

Auxiliary power supply

Isolated DC source only

Auxiliary supply input voltage

18 to 30 VDC

Auxiliary supply input power

< 8 VA (this includes the 5 V/2x200 mA load for
the main and auxiliary encoders)

Note:

An S-type drive will not operate unless it has the Aux. supply (Mandatory).

4.4. Environmental Conditions

Feature

Details

Operating ambient temperature

according to IEC60068-2-2

0 °C to 40 °C (32 °F to 104 °F)

Storage temperature

-20 °C to +85 °C ( -4 °F to +185 °F)

Maximum non-condensing humidity

according to IEC60068-2-78

95%

Maximum Operating Altitude

2,000 m (6562 feet)

Mechanical Shock

according to IEC60068-2-27

15g / 11ms Half Sine

Vibration

according to IEC60068-2-6

5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G

Advertising