Figure 14: Timer Delay

example #4

The following program uses a Count-Up and a Count-Down instruction to keep track of the

number of acceptable widgets produced. As a widget comes down the production line, an opti-

cal sensor on input 6 senses the widget and makes the XIC instruction true, which increments

Counter 5. When widgets are rejected, they are diverted down another conveyor with an opti-

cal sensor on input 10. When the reject sensor sees a widget, it decrements Counter 5. With

this configuration the counter is able to keep track of the acceptable widgets produced. A reset

button on input 12 resets the counter to 0.

Figure 15: Count-Up/Count-Down instruction