Module removal and installation, Removal, Module removal and installation -3 – Rockwell Automation 160 SSC Series C FRN 7.xx User Manual

Page 35: Removal -3

Advertising
background image

Program Keypad Module

3-3

Module Removal and Installation

Removal

Insert a small screw driver into the slot at top of keypad. Carefully pry back and
pivot the module out. Avoid bending or twisting the contact pins located underneath
the center portion of the module.

Removing Program Keypad Module

Figure 3.2

ATTENTION: Ensure that you disconnect line power and wait three
minutes before installing or removing the Program Keypad Module.
Failure to do so could result in personal injury or death.

ATTENTION: This drive contains ESD (Electrostatic Discharge)
sensitive parts and assemblies. Static control precautions are required
when installing, testing, servicing or repairing this assembly.
Component damage may result if ESD control procedures are not
followed. If you are not familiar with static control procedures,
reference Publication 8000-4.5.2, “Guarding Against Electrostatic
Damage” or any other applicable ESD protection handbook.

SE

L

ES

C

Advertising