Troubleshooting

6-3

Possible Problems and Corrective Actions

Table 6.B

Problem

Corrective Action

The motor does not start — No output voltage to the
motor.

1. Check the power circuit.

• Check the supply voltage.
• Check all fuses and disconnects.

2. Check the motor.

• Verify that the motor is connected properly.

3. Check the control input signals.

• Verify that the Start signal is present.
• Verify that the contact closure signal is present at TB3-8.

• Verify that either the Run Forward or Run Reverse signal is

active, but not

both.

4. Check P46 - [Input Mode].

• If P46 - [Input Mode] is set to 2, only the program keypad module Start button

will start the motor.

5. Cycle power or use P56 - [Reset Functions] if you changed

P46 - [Input Mode].

The drive is started but the motor is not rotating.
P01 - [Output Frequency] displays 0.0.

1. Check the motor.

• Verify that the motor is connected properly.

2. Check the frequency source P06 - [Frequency Command].

• Verify that a frequency signal is present at terminal block TB3 — Either a

-10 to +10V signal or a 4-20 mA signal.

• Verify that the Preset Frequencies are set properly.

3. Check the control input signals.

• Verify that SW1, SW2 and SW3 are correct. (Refer to the chart in Chapter 5.)

4. Check the following parameter settings.

• Verify that P59 - [Frequency Select] is showing the desired frequency source.
• Verify that P58 - [Internal Frequency] is set to the desired frequency.

5. Cycle power or use P56 - [Reset Functions] if you changed

P46 - [Input Mode].

The motor is not accelerating properly.

1. Check the motor.

• Verify that the motor is connected properly.
• Verify that no mechanical problems exist.

2. Check the following parameter settings.

• Verify that P30 - [Accel Time 1] or P69 - [Accel Time 2]

— whichever is currently used — is set properly.

• Verify that P43 - [Current Limit] is set properly.
• Verify that P38 - [Boost Volts] is set properly.

Drive will not operate in the run/forward or run reverse
modes.

1. Verify that P46 - [Input Mode] is set to 1.

2. Verify that neither P73 - [Reverse Disable] nor P74 - [Analog Select] is set to 1.

3. Verify that the power has been cycled for 1and 2 to take effect.

4. Verify that both the Run Forward and Run Reverse switches are not closed

simultaneously.

5. Cycle power or use P56 - [Reset Functions] if you changed

P46 - [Input Mode].

Display is dark.

1. Verify that the module is firmly seated.

2. Remove module and inspect connector pins. If pins are not damaged, reinstall

and firmly seat the module.

Advertising