Specifications

Controller Specifications

Table A.1 General Specifications

Description

1764-24BWA

1764-24AWA

1764-28BXB

Number of I/O

12 inputs
12 outputs

12 inputs
12 outputs

16 inputs
12 outputs

Line Power

85 to 265V ac
at 47 to 63 Hz

85 to 265V ac
at 47 to 63 Hz

20.4 to 30V dc

Power Supply
Usage

88 VA

70 VA

30W

(2)

Power Supply Inrush 120V ac = 25A for 8

ms
240V ac = 40A for 4
ms

120V ac = 25A for 8
ms
240V ac = 40A for 4
ms

24V dc = 4A for 150
ms

User Power Output

24V dc at 400 mA,
400 µF max.

none

none

Input Circuit Type

24V dc, sink/source

120V ac

24V dc, sink/source

Output Circuit Type

relay

relay

6 relay, 6 FET
transistor
(24V dc source)

Typical CPU Hold-up
Time

10 to 3000 ms

Operating Temp.

+0°C to +55°C (+32°F to +131°F) ambient

Storage Temp.

-40°C to +85°C (-40°F to +185°F) ambient

(1)

Operating Humidity

5% to 95% relative humidity (non-condensing)

Vibration

Operating: 10 to 500 Hz, 5G, 0.030 in. max. peak-to-peak
Relay Operation: 2G

Shock (without Data
Access Tool
installed)

Operating: 30G panel mounted (15G DIN Rail mounted)
Relay operation: 7.5G panel mounted (5G DIN Rail mounted)
Non-Operating: 40G panel mounted (30G DIN Rail mounted)

Shock (with Data
Access Tool
installed)

Operating: 20G panel mounted (15G DIN Rail mounted)
Relay operation: 7.5G panel mounted (5G DIN Rail mounted)
Non-Operating: 30G panel mounted (20G DIN Rail mounted)

Agency Certification

UL 508

C-UL under CSA C22.2 no. 142

Class I, Div. 2, Groups A, B, C, D

(UL 1604, C-UL under CSA C22.2 no. 213)

CE compliant for all applicable directives

C-Tick marked for all applicable acts