Services, Relay object (class id 323h), Relay object (class id 323 – Rockwell Automation 1440-TPS02-01RB XM-320 Position Module User Manual

Page 110

Advertising
background image

Publication GMSI10-UM005C-EN-P - May 2010

102 DeviceNet Objects

Services

Relay Object
(Class ID 323

H

)

The Relay Object models a relay (actual or virtual). A relay can be activated or
deactivated based on the status of one or more alarms.

Table C.34 Device Mode Object Services

Service
Code

Class/Instance Usage

Name

Description

0E

h

Instance

Get_Attribute_Single

Return the value of a single
attribute.

10

h

Instance

Set_Attribute_Single

Set the value of a single
attribute.

07

h

Instance

Stop

Transitions from Run to the
Program state.

06

h

Instance

Start

Validate the device
configuration settings and
transition to the Run state if
OK.

05

h

Instance

Reset

Transition to the Power Up
state. Load the non-volatile
configuration and transition
to the Run state if saved
configuration restored.

16

h

Instance

Save

Validate the device
configuration settings if
necessary and save them to
non-volatile memory.

09

h

Instance

Delete

Delete the saved
configuration from
non-volatile memory.

15

h

Instance

Restore

Load the saved
configuration or the factory
default configuration from
non-volatile memory.

Advertising