Threshold, Fixed, Adaptive – Banner PresencePLUS P4 COLOR Series User Manual

Page 127

Advertising
background image

Description

Control

Use this field to rotate the ROI. You can manually key in
a rotation angle, or you can use the up or down arrow keys
to rotate the ROI.

Threshold

Type

Fixed

Select Fixed when the lighting and image content will remain relatively constant for all inspections.

If you select Fixed , you can also specify Threshold and Reject Levels.

Threshold Level

The Threshold Level (e.g., 141) defines the white/black cutoff point. Once a threshold is chosen, any pixels brighter
than the threshold become pure white while those darker than the threshold become pure black.

Reject Level

The Reject Level field is for bright Blobs only, and is used to narrow the range of pixel intensities to consider in an
inspection. Leaving the defaults at 0 for low and 255 for high will result in the tool taking into consideration all gray
scale levels in the ROI from 0 (black) to 255 (white). Note that the Reject Level field is visible only when Bright bead
type is selected.

Adaptive

Select Adaptive when there are lighting changes that cause the acquired image to change.