Banner PresencePLUS P4 COLOR Series User Manual

Page 322

Advertising
background image

Comments

Optional
Qualifiers

Required
Qualifiers

Support Actions

Object or
Activity
Identifier

System Object,
Component, or
Activity

By default, a 30
second timeout is
used.

Timeout (msec)

or

NOWAIT

Numeric Inspection
ID

EXEC

PRODCHANGE

Product Change

Reset either the
System Error Flag,

None

SYSERRFLG

or

EXEC

RESET

Counter or Flag
Reset

Pass and Fail

PASSFAILCNT

counters, or
Missing Trigger
count.

or

MISSTRIGCNT

Enables remote
teach. If no

TRIGGER or
TRIGGER

None

EXEC

RTEACH

Remote Teach

qualifiers are

NOWAIT or

specified, remote

TRIGGER
Timeout (msec)

teach will occur on
the next trigger. If
TRIGGER
qualifier is
specified, remote
teach will occur
immediately, and
the command will
block until a
default 30-second
timeout expires. If
TRIGGER
NOWAIT is
specified, remote
teach will occur
immediately, and
the command will
return right away.
If a timeout value
is specified, the
command will
block until the
specified timeout
expires.

Retrieve the sensor
online status.

None

None

GET

ONLINESTS

Online Status

Returns 1 if the
camera is ready, 0
otherwise

None

None

GET

READYFLG

Ready State

Retrieve currently
running inspection

None

None

GET

INSPNUM

Current
Inspection
Number