Industrial ethernet – Banner PresencePLUS P4 COLOR Series User Manual

Page 53

Advertising
background image

Note:

Because there is no flow control for the serial connections, the sensor wil not detect or log a lost or broken
connection

Industrial Ethernet

Protocol

Protocol selects which Industrial Ethernet protocol is being used. This changes the string format and the word/register
values reported in the PLC Map.

32 bit Format

32 bit Format determines how 32 bit integers and floating point values are stored in sequential 16 bit registers (words)
- least significant word first (LSW-MSW) or most significant word first (MSW-LSW).

Character String Order

For Modbus/TCP and PCCC protocols, characters in the string can be packed into registers according to either the
Standard String format or the ControlLogix Format1:

• Standard String Format is used when the Character String Order option is set to “High Byte – Low Byte” selection.

Please note that the length of the string is stored in one 16-bit register:

• ControlLogix packing format is used to store characters into registers when the Character String Order option is set

to “Low Byte – High Byte” selection.

Please note that in this particular case, the length of the string is still stored in one 16-bit register, and only
the order of characters in each 16-bit register follows the ControlLogix format:

53