2 adding a tool, 3 adding a test tool, 4 renaming tools – Banner PresencePLUS P4 COLOR Series User Manual

Page 40: 5 removing a tool, 3 quick teach

Advertising
background image

Note: Test tool must be chosen to evaluate the results of each tool or set of tools.

5.2.2 Adding a Tool

The following steps provide an overview for setting up tools in an inspection. Steps not available for some of the
Location or Analysis tools are noted.

1. Click the button of the tool to be added to the inspection.

2. Rename the tool.
3. Draw the ROI (not available for Analysis tools).

4. Set Input options to indicate the expected results (not available for the Test tool).

5. Add a Test tool.
6. Configure the Test tool inputs and, if desired, configure the desired results.

7. Set the judgment tolerances in one of three ways:

• Use Quick Teach.

• Use Teach.

• Manually set the judgment tolerances.

5.2.3 Adding a Test Tool

The following steps provide an overview for adding a Test tool to an inspection.

1. Add a Test tool.
2. Configure the Test tool inputs.
3. Set the judgment tolerances.

5.2.4 Renaming Tools

The default name of each tool can be edited or replaced (examples: GS_1, TT_2). Each name must be unique.

To edit the tool name, click on the Name field (double-click to select the entire name), and type to change or replace
the name.

• Enter up to 49 characters; only alphanumeric characters and underscores are valid.
• The button in the Navigation/Results window that appears will show the first nine characters after exiting the tool.

5.2.5 Removing a Tool

To remove a tool:

1. Choose the tool to be removed in the Navigation/Results window.
2. Click the Delete button in the lower-left corner of the screen.

5.3 Quick Teach

Quick Teach provides the fastest and easiest method of establishing an inspection. Quick Teach will use the reference
image to establish Pass/Fail parameters of the Test tools.

Quick Teach does the following:

• Executes the inspection on the reference image.

• “Learns” the results of the Vision tools.

• Applies the applicable tolerances (user-determined, but default is 10%) to the selected parameters in the Test tool

(these parameters determine the Pass/Fail criteria for each Test tool within the inspection).