• In the sequence that the tools are selected within the Communication tool.

• In the sequence that the options are listed within the tools for export

One inspection can have more than one Communication tool.

Use one Communication tool to:

• Export data out of one port (serial or Ethernet).

• Export identical data out of multiple ports at the same time.

Use multiple Communication tools to:

• Separate the data and export separate segments to unique external devices.

• Customize the order of the exported data.

• Export data from the Vision tools at different times during the inspection.

• Customize the “Start Strings” control characters to unique external devices.

Note: The Test tool can have the Communication tool as one of its inputs. Therefore, if a Test tool is added after
the Communication tool, a discrete output can be activated:

• If the TCP/IP connection is lost.

• If the external device fails to acknowledge it received data.

This output could contribute to an inspection Pass/Fail if it is an input to a Test tool. A Communication tool without
a Test tool will not contribute to the inspection Pass/Fail.

Select

This field provides a drop-down list from which to select tools; select the results to export from the selected tool’s tab
that appears in the configuration window.

Connections

This field provides a drop-down list from which to select the communication connection(s) to export the data.

Banner Engineering Corp.