Banner PresencePLUS P4 COLOR Series User Manual

Page 323

Advertising
background image

Comments

Optional
Qualifiers

Required
Qualifiers

Support Actions

Object or
Activity
Identifier

System Object,
Component, or
Activity

Retrieve comm
tool results, either

CommTool
Numberor

None

GET

COMMTOOL

Communications
Tool Results

by specifying its

CommTool
Name

sequential number
in the inspection
(1,2,..,n) or by
specifying its
name. By default,
data for the first
comm tool will be
retrieved.

Retrieve the value
of the Pass/Fail

None

None

GET

PASSFAILFLG

Pass/Fail flag

flag - 1 if pass, 0 if
fail

Retrieve the value
of the System

None

None

GET

SYSERRFLG

System Error

Error - either 0 or
1

Retrieve the
current frame
number

None

None

GET

FRAMENUM

Frame Number

Retrieve the pass
count

None

None

GET

PASSCNT

Pass Count

Retreive the failed
count

None

None

GET

FAILCNT

Fail Count

Retrieve the
Iteration Count

None

None

GET

ITERCNT

Iteration Count

Retrieve the
system error count

None

None

GET

SYSERRCNT

System Error
Count

Retrieve the
missed trigger
count

None

None

GET

MISSTRIGCNT

Missed Trigger
Count

Retrieve the
cached status of
the I/O line

None

I/O line id,
numeric, either 1
through 4 or 1
through 6

GET

IOSTS

I/O Line Status

Retrieve the gain

None

GET

GAIN

Gain

Set the gain

None

Positive Integer

SET

GAIN

Gain

Retrieve the
camera exposure

None

GET

EXPOSURE

Exposure

Get the camera
exposure

None

Positive Number

SET

EXPOSURE

Exposure

323

Minneapolis, MN USA

Banner Engineering Corp.

Communication Tool Setup

2/2010

Advertising