Select the state (open or closed) that the output will take when not active.

Normally Open/Closed

Normally Open: The output becomes active when the logic condition controlling the

output becomes True.

Normally Closed: The output becomes inactive when the logic condition controlling

the output becomes True.

Output Delay is the time from a trigger to start an inspection until the Sensor output turns ON.
It is available only for general outputs.

Output Delay

Note: If processing time is longer than the output delay, the output will become active
immediately after the processing is finished.

This option is available only for the general outputs; the other outputs (Pass, Fail, System Error, and
Ready) are latched only.

Output
Duration

Latched: Active until the condition changes.

Time: Active for a specific length of time.

ON

OFF

OFF

ON

Trigger

Output

Output Duration

Processing Time

Delay

Latched

Input/Ouput Tab

P4 Input/Output Tab

77