Enabling remote teach, Rotation enabled, Minimum acceptance level – Banner PresencePLUS P4 COLOR Series User Manual

Page 169: Patterns

Advertising
background image

Description

Field/Button

Click this button to remove an ROI from an image.

Use this field to rotate the ROI. You can manually key in
a rotation angle, or you can use the up or down arrow keys
to rotate the ROI.

Enabling Remote Teach

The Remote Teach function is a method of remotely updating inspection parameters in Run mode. Vision tools and
Test tools can be selected to be taught or not taught. To remotely teach an inspection, the Remote Teach function must
be enabled on each tool to be taught.

Rotation Enabled

The Pattern Find tool has a +/- 10 degree rotation ability. All subsequent ROIs will rotate relative to the edge found.
During setup, the tool calculates the angle of the pattern found. During inspection, the new angle is compared to the
original angle. If there is any rotational change between the new angle and the original angle, all subsequent ROIs will
rotate that amount.

Minimum Acceptance Level

This adjustment sets the acceptance level for pattern matches.

• Decrease the Minimum Acceptance Level to allow more variations in matching patterns.
• Increase the Minimum Acceptance Level to filter out patterns that contain small defects.

Percent match is a value between 20% and 100% that indicates the quality of the match (100% is a perfect match; 20%
is a slight match). The percent match can be used to detect large defects.

Note: Banner does not recommend setting the Minimum Acceptance Level below 70%.

Patterns

In Maximum Number of Patterns to find field, manually key in a value or use the up or down arrow keys to specify
the number of patterns to find.