6.3.1 P4 Input/Output Tab

Use this tab to set t he functionality of the four programmable I/O connections.

You can select Trigger, Product Change, Remote Teach, and Discrete inputs and outputs
as eith NPN (current sourcing) or PNP (current sinking). Once NPN or PNP is selected,
all inputs and outpus are either NPN or PNP.

Inputs and Outputs

I/O 1 through 4 in the I/O column correspond to Pins 5 through 8 in the Pin # column.

I/O, Pin #,
Function

Options from the drop-down list are:

General Input: Input to the sensor.
General Ouput: Output from the sensor that can be selected in a Test tool.
Pass: Active when the entire nspection passes.

Fail: Active when the inspection fails.

System Error: Active when a system error occurs.

Ready: Active when the sensor is ready to accept another trigger.

Product Select: Used in conjunction with Product Change to select inspection locations at which

to begin execution.