8-28 ADS FlowShark Pulse O&M Manual

The percent setting defines the relative weighting of each sensor in relation to the
velocity profile.

The weighting of individual sensor velocities depends primarily upon the geometry of
the channel and sensor placement. Contact ADS for assistance in assigning
weighting for each sensor.

Parameter Menu: Analog Inputs

Figure 8-40 Analog inputs – submenu

Based on the transmitter type, several analog inputs may be available. For example,
the Model 10 transmitter includes the following inputs:

z

1 analog input (galvanically isolated) for two-wire sensors

z

1 additional analog input for external depth sensor connection

Model 20 transmitters include the following inputs:

z

1 analog input (galvanically isolated) for two-wire sensors

z

4 additional analog inputs for external depth sensor connection and external
setpoints or analog data storage.

The user can choose and select settings for any analog input,
regardless of the transmitter in use (for example, Model 10
transmitters have only 2 analog inputs).

If an external depth sensor (connection: AI1) has been enabled for
a Model 10 transmitter in the Level menu in the past, an analog
input parameter will no longer be available in the settings.

Function, measurement range, control signal span, and other parameters may be set
for each analog input. It also is possible to linearize each input stage independently.