Use and Specifications 2-5

Combi Sensor/Pipe Insertion Sensor

Measurement

Principle

• Ultrasonic transit time (depth measurement) – Combi Sensor

only

• Piezoresistive pressure measurement (depth measurement) –

Combi sensor only

• Correlation with digital pattern detection (flow velocity)

Measurement

Frequency

1 MHz

Protection Rating IP 68

Ex-Approval

(optional)

II 2 G EEx ib IIB T4

Operating

Temperature

-4° to 122° F (-20° to +50° C) (104° F (40° C) in Ex Zone 1)

Storage

Temperature

-22° to 158° F (-30° to +70° C)

Operating

Pressure

Maximum 58 psi (4 bar) (combi sensor with pressure element
maximum 14 psi (1 bar))

Cable Length

33/66/99/165 feet (10/20/30/50 m), extendable up to 820 feet (250
m); sensors with pressure measurement require pressure
compensation element junction box

Cable Types

• Sensors with pressure measurement:

LiYC11Y 2x1.5 + 1x2x0.34 + PA 1.5/2.5

• Sensors without pressure measurement:

LiYC11Y 2x1.5 + 1x2x0.34

Outside Cable

Diameter

• Sensors with pressure measurement:

0.34 ±0.01 inches (8.7 ±0.25 mm)

• Sensors without pressure measurement:

0.3 ±0.01 inches (7.6 ±0.25 mm)

Sensor Types

• Flow velocity sensor with velocity measurement using cross-

correlation and temperature measurement to compensate for the
effect of temperature on the velocity of sound

• Combi sensor with flow velocity sensor using cross-correlation,

depth measurement via water-ultrasonic, and temperature
measurement to compensate for the effect of temperature on the
velocity of sound (combi sensor only)

• Combi sensor with flow velocity sensor using cross-correlation,

depth measurement via pressure, and temperature
measurement to compensate for the effect of temperature on the
velocity of sound (combi sensor only)

• Combi sensor with flow velocity sensor using cross-correlation,

Advertising