6-20 ADS FlowShark Pulse O&M Manual

1

Shield connection screws

2 Air

hose

3 Transmitter

side

4 Terminal

clamps

5

Flow velocity sensor side

Figure 6-25 Open connection box

Run an extension between the connection box and the transmitter using A2Y or
similar appropriately shielded signal cables. After connecting the cables, secure the
air filter onto one of the cables with the cable clips so that the opening of the filter
element faces downward. Snap the air hose plug into the socket on the lid of the box
lid, and then screw the lid onto the box.

Figure 6-26

Assembled pressure compensation element

Install the connection box in an area with reliable flood protection.

Never operate the pressure compensation element with the air hose
unplugged. The automatic self-locking mechanism of the
integrated socket will shift the zero point for the depth
measurement.

The opening of the filter element must always face downward.