Installation 6-23

The pressure compensation element also serves as a connection
socket for the cable extension. Run no more than 750 feet (250 m)
of cable between the sensor and transmitter to avoid exceeding the
maximum permissible resistance
.

not occupied

D1

D2

D3

D4

D5

D6

D7

not occupied

outer shield

supply +

UE-GND

RxTx -

RxTx +

FlowShark Pulse

white

green

blue

red

black (shield, no earth)

8.6 V

LIYC 11Y 2 1.5mm

.

2

+1 2 0.34mm

.

2

.

max. 328 ft

air ultrasonic sensor

Figure 6-31 Connecting an air-ultrasonic sensor

Refer to the following wiring diagram to perform depth measurements using a 2-wire
probe provided by a reputable supplier:

+ 22 V Ex

D9

D8

AI 5 Ex

FlowShark Pulse

A2Y 2 x 2 x 0.8 or similar,

I = 4 - 20mA

2-wire sensor or pressure probe

for the direct connection

of intrinsically safe sensors

(EEx ia IIB)

loop powered

max. 492.15 ft (150m)

Figure 6-32 Connecting an external 2-wire sensor (Ex) for flow depth measurement

+

a14

b15

-

FlowShark Pulse

A2Y 2 x 2 x 0.8 or similar,

I = 4 - 20mA

2-wire sensor or pressure probe

no

max. 492.15 ft (150m)

+

a18

b16

-

24 V DC

insert

wire bridge

Ex !

Figure 6-33 Connecting an external 2-wire sensor (non-Ex) for flow depth measurement

If an external transmitter provides the mA signal for depth measurement, connect to
the clamps in the following way: