Day values – ADS Environmental Services FlowShark Pulse QR 775004 A1 User Manual

Page 96

Advertising
background image

8-6

ADS FlowShark Pulse O&M Manual

very good profile, area

free of backwater

good profile, strongly

tending to backwater

suitable profile

Ill-suited profile

unsuitable profile

Figure 8-5 Flow velocity profiles

Day Values

Select the INFO submenu from the day values menu (Figure 8-6). This screen
displays the flow totals for the past 7 days (Figure 8-7), provided the transmitter has
operated without interruption for the past 7 days. If an interruption occurs, it displays
the flow totals for the uninterrupted days of operation.

Flow totals typically are calculated at midnight (00:00 h). Modify the time at which
this will occur, if necessary, through the RUN > Day Values > Interval (Figure 8-8).

The user also can obtain partial totals since the last reset. Reset the total to 0 by
pressing the ALT key. This reset does not modify the totalizer.

Figure 8-6 Info menu

Figure 8-7 Day values

Advertising