CLS-420 Installation Manual

Acquire Tare

1. Place container on scale and wait for the standstill annunciator (

).

2. Press the

TARE

key to acquire the tare weight of the container. Net weight is displayed and net annunciator

is lit.

Remove Stored Tare Value

1. Remove all weight from the scale and wait for the standstill annunicator.

2. Press the

TARE

key. The Gross annunicator is lit.

Set Date

In the front panel setup mode, use the arrow keys to toggle to

DATE

. Press the

Down

arrow or

Enter

to enter the date

in the format configured for the indicator.

Set Time

In the front panel setup mode, use the arrow keys to toggle to

TIME

. Press the

Down

arrow or

Enter

to enter the time

in 24-hour format, then press the

Enter

key to save that value.

Display Accumulator

Hold the

(MODE) GROSS/NET

key for three seconds to display the accumulated valued if enabled in configuration.

The accumulated value will be displayed for about 10 seconds. To clear the accumulator, press the

CLR

key twice

while the accumulated value is being displayed.

1.3.4

Modes of Operation

The 420 has four modes of operation:

Normal (Primary) mode

Normal mode is the “default” mode of the indicator. The indicator displays gross or net weights as required,
using the LED annunciators described in Section

1.3.2 on page

5 to indicate scale status and the type of weight

value displayed. Once configuration is complete and a legal seal is affixed to the back of the indicator, this is
the primary mode in which the 420 can operate.

Setup mode

Most of the procedures described in this manual require the indicator to be in setup mode, including
configuration and calibration.

To enter setup mode, remove the setup screw and insert a small screwdriver pressing the setup switch once.
The indicator display changes to show the word

CONFIG

.

Test mode

Test mode provides a number of diagnostic functions for the 420 indicator. Like setup mode, test mode is
entered using the setup switch. See Section

8.9 on page

49 for more information about entering and using test

mode.

NOTE

: Test mode is intended for factory and technician use only.

Front Panel Setup Mode

Hold the

UNITS

key for three seconds to enter front panel setup mode. Use front panel setup to change setpoint

and to set the time and date.

Note

This can be done without breaking the seal.