4 serial menu, Serial menu – Rice Lake CLS-420 Cargo Lift Scale Installation Manual User Manual

Page 39

Advertising
background image

CLS-420 Installation Manual

29

5.2.4

SERIAL Menu

Figure

5-8 illustrates the serial menu and their associated settings for the functionality of the CLS-420 Cargo Lift

Scale. It should be noted that the EDP port is dedicated to the two channel iQube communication and is
automatically set when the SSCALE parameter is set to 2LCELL.
Table

5-5 below, illustrates the different serial

settings used for CLS functionality and a basic 420 indicator.

XXXXXXX

XXXXXXX

XXXXXXX

XXXXXXX

EOLDLY

000

number

EDP

PRINT

PRN

EDP

PRNDES

BITS

TERMIN

BAUD

CR

9600

7ODD

7EVEN

8NONE

CR/LF

4800

2400

1200

600

300

Same as EDP

EDP

OFF

STREAM

PRN

ALGOUT

DIGIN

SETPNT

PROGRM

PFORMT

SERIAL

CALIBR

CONFIG

FORMAT

ECHO

ON

OFF

VERS

19200

38400

The print port is labeled Serial to the CPU board.

2LCELL

OFF

SSCALE

4LCELL

LFT

INDUST

STRRTE

OFF

ON

SS-LFT

OFF

ON

PRNMSG

Figure 5-8. CLS-420 SERIAL Menu

Table 5-5. SSCALE Parameter Settings

SSCALE Parameter Settings

Parameter

If set to OFF

If set to 2LCELL

Baud

9600

19200

Bits

8 None

8 None

Termin

CR/LF

CR

EOLDLY

000

000

Echo

On

Off

Note

The SSCALE parameter on the serial menu must be set to 2LCELL for use with the CLS-420 Cargo Lift Scale. If
it is set to OFF, then the 420 indicator will function with a standard 420 calibration menu.

Advertising