Table 5-6. Serial Menu Parameters

SERIAL Menu

Parameter

Choices

Description

Level 2 submenus

EDP -
dedicated to
the two
channel
iQube

BAUD
BITS
TERMIN
EOLDLY
ECHO

Specifies settings for baud rate, data bits, termination characters, end-of-line delay and echo
used by the EDP port.

PRINT

BAUD
BITS
TERMIN
EOLDLY
ECHO

Specifies settings for baud rate, data bits, termination characters, end-of-line delay, and echo
used by the printer port.

STREAM

OFF
EDP
PRN

Selects the serial port used for continuous transmission. See Figure

8.3 42 for information

about the 420 continuous data format.

STRRTE

INDUST
LFT

Specifies stream rate. Stream rate can be set to industrial or legal for trade.

PRNDES

EDP
PRN

Print destination. Selects the port for data transmission when the print key is pressed or the
KPRINT EDP command is sent.

PRNMSG

ON
OFF

Print message. Default will be ON. When the print key is pressed and data is sent out, the
word PRINT is momentarily displayed on the remote display.

SSCALE

OFF
2LCELL
4LCELL

By selecting this option, it enables the scale to be used by the CLS series cargo lift scale.

SS-LFT

ON
OFF

This parameter turns off the LFT 3 degree tilt warning.

Level 3 Submenus

EDP Port and Printer Port

BAUD

9600- Printer
19200 - EDP
28800
38400
57600
115200
300
600
1200
2400
4800

Baud rate. Selects the transmission speed for the port.

BITS

8NONE
7EVEN
7ODD

Selects number of data bits and parity of data transmitted or received by the port.

TERMIN

CR/LF -
Printer
CR - EDP

Termination character. Selects termination character for data sent from the port.

EOLDLY

000000
0–255

End-of-line delay. Sets the delay period, in 0.1-second intervals, from when a formatted line is
terminated to the beginning of the next formatted serial output. Value specified must be in the
range 0-255, in tenths of a second (10 = 1 second).

ECHO

OFF - EDP
ON - Printer

This command enables or disables echoing of the serial commands sent to the indicator.