3 charging the lithium-ion battery, 4 calibrating the lithium-ion battery, Charging the lithium-ion battery – Rice Lake CLS-420 Cargo Lift Scale Installation Manual User Manual

Page 22: Calibrating the lithium-ion battery

Advertising
background image

17

CLS-420 Installation Manual

3.5.3

Charging the Lithium-Ion Battery

The lithium-ion battery comes with a two-bay, level-3 stand alone smart battery charger, a DC power jack, and a
AC power cord as shown in Figure

3-9.

To calibrate the
battery pack,
press the button
on front label.
See Section
3.5.4

Figure 3-9. Two-Bay Battery Charger and Parts for the Lithium-Ion Battery

The average charge time for the battery is three hours each.
Use the following steps to charge the battery prior to use:

1. Insert the plug end of the power cable into the DC power jack on the battery charger and the AC plug into

an outlet.

2. Insert battery into the bay.
3. There is one LED indicator in front of each bay which will illuminate to indicate the status of the battery as

follows:

Table 3-3. Battery Charging LED Signals

Signal

Description

Off

No Battery

Green Flashing

Fast Charging

Green Solid

Fully Charged

Yellow Flashing

Recalibrating

Yellow/Green Alternating

Recalibrating

Yellow Solid

Standby

Red Flashing

Error

3.5.4

Calibrating the Lithium-Ion Battery

In order to keep the battery fuel gauge as accurate as possible, it is necessary to occasionally run the pack through a
recalibration cycle. To do this, place the battery in the left bay of the charger and press the button on the front label
(see Figure

3-9). This will initiate the recalibration sequence in the left bay only. The process can take up to nine

hours to complete and a recommended recalibration should be done once quarterly to keep the battery accurate.