9 test mode – Rice Lake CLS-420 Cargo Lift Scale Installation Manual User Manual

Page 59

Advertising
background image

CLS-420 Installation Manual

49

8.9

Test Mode

Note

Test mode is intended for factory use only.

In addition to normal and setup modes, test mode provides a number of diagnostic functions for the

920i

, including:

• Display raw A/D count

• Reset configuration parameters to default values

• A/D internal calibration

To enter test mode, press and hold the setup switch until the front panel display shows the word

TEST

. After about

three seconds, the test mode display automatically shifts to the first test menu function, A/DTST.

Figure

8-6 shows the Test Menu structure; Figure

8-7 shows the front panel key functions in test mode. Note that,

because the Test Menu functions are all on a single menu level, the

GROSS/NET

( ) key has no function. Press the

ZERO

( ) key to exit test mode.

Table

8-7 summarizes the test menu functions.

"%545

5&45

"%0''4

"%("*/

%&'-5

Figure 8-6. Test Mode Menu

&YJU

&/5&3

.PWF-&'5

.PWF3*()5

/PU6TFE

Figure 8-7. Front Panel Key Functions in Test Mode

TEST Menu

Function

Description

A/DTST

Display A/D test
Press and hold Enter key to display raw count from A/D converter.

DEFLT

Default parameters
Press setup switch and Enter key at the same time to reset configuration and calibration parameters to factory
default values. Load cells must be recalibrated before using the indicator (see Section

6.0 on page

38).

Table 8-7. Test Mode Menu Functions

Advertising