9 test mode – Rice Lake CLS-420 Cargo Lift Scale Installation Manual User Manual
Page 59
CLS-420 Installation Manual
49
8.9
Test Mode
Note
Test mode is intended for factory use only.
In addition to normal and setup modes, test mode provides a number of diagnostic functions for the
920i
, including:
• Display raw A/D count
• Reset configuration parameters to default values
• A/D internal calibration
To enter test mode, press and hold the setup switch until the front panel display shows the word
TEST
. After about
three seconds, the test mode display automatically shifts to the first test menu function, A/DTST.
Figure
8-6 shows the Test Menu structure; Figure
8-7 shows the front panel key functions in test mode. Note that,
because the Test Menu functions are all on a single menu level, the
GROSS/NET
( ) key has no function. Press the
ZERO
( ) key to exit test mode.
Table
8-7 summarizes the test menu functions.
"%545
5&45
"%0''4
"%("*/
%&'-5
Figure 8-6. Test Mode Menu
&YJU
&/5&3
.PWF-&'5
.PWF3*()5
/PU6TFE
Figure 8-7. Front Panel Key Functions in Test Mode
TEST Menu
Function
Description
A/DTST
Display A/D test
Press and hold Enter key to display raw count from A/D converter.
DEFLT
Default parameters
Press setup switch and Enter key at the same time to reset configuration and calibration parameters to factory
default values. Load cells must be recalibrated before using the indicator (see Section
Table 8-7. Test Mode Menu Functions