4 routing the power/serial communications cable – Rice Lake CLS-420 Cargo Lift Scale Installation Manual User Manual

Page 19

Advertising
background image

CLS-420 Installation Manual

14

A supplied in-line fuse is also included with the CLS-series cargo lift scale. The fuse comes enclosed in an in-line
fuseholder (shown in Figure

3-5) and is attached where the stripped termination of the wires is located.

Replacement of the in-line fuse is described in the CLS-Series Service manual if needed.

Figure 3-5. Inline Fuse

Attach the three stripped wires to the forklift battery using the following wire code

Note

Supplied termination hardware includes (3) 1/4" eyelets for 1/4" bolts.

Table 3-1. Power Hookups to Forklift Battery

Wire Color

Signal

Red

Positive on Battery

Black

Negative on Battery

Blue

Chassis Ground

3.4

Routing the Power/Serial Communications Cable

Special care should be taken when routing the power/serial communications cable (if the standard coil wired
version is used
). To ensure that the signal cable is installed properly and away from situations that could cause it
harm use the following steps.

1. Mount the indicator to the forklift per instructions in Section

3.1.

2. Lay the coiled up signal cable along the route between the indicator and the forklift scale.

Figure 3-6. Power/Serial Communications Cable

Note

The preferred route is through the center of the mast. If it has a three stage mast, route alongside the mast as
shown in Figure

3-7.

Advertising