14
A supplied in-line fuse is also included with the CLS-series cargo lift scale. The fuse comes enclosed in an in-line
fuseholder (shown in Figure
3-5) and is attached where the stripped termination of the wires is located.
Replacement of the in-line fuse is described in the CLS-Series Service manual if needed.
Figure 3-5. Inline Fuse
Attach the three stripped wires to the forklift battery using the following wire code
Note
Supplied termination hardware includes (3) 1/4" eyelets for 1/4" bolts.
Table 3-1. Power Hookups to Forklift Battery
Wire Color
Signal
Red
Positive on Battery
Black
Negative on Battery
Blue
Chassis Ground
3.4
Routing the Power/Serial Communications Cable
Special care should be taken when routing the power/serial communications cable (if the standard coil wired
version is used). To ensure that the signal cable is installed properly and away from situations that could cause it
harm use the following steps.
1. Mount the indicator to the forklift per instructions in Section
3.1.
2. Lay the coiled up signal cable along the route between the indicator and the forklift scale.
Figure 3-6. Power/Serial Communications Cable
Note
The preferred route is through the center of the mast. If it has a three stage mast, route alongside the mast as
shown in Figure
3-7.