Rice Lake CLS-420 Cargo Lift Scale Installation Manual User Manual

Page 44

Advertising
background image

34

CLS-420 Installation Manual

ENABLE

OFF
ON

Turn setpoint on or off.

KIND

GROSS
NET

Specifies the setpoint kind and determines whether function is based on GROSS or NET
weight.
GROSS or NET setpoint kinds can be used.

VALUE

number

Display and edit the setpoint value.

TRIP

HIGHER
LOWER
INBAND
OUTBND

Trips the setpoint when the weight is higher or lower than the setpoint value, or is within or
outside of the band value. LOWER means the output is active until you reach weight. If
trip is HIGHER, the output is active when the setpoint is met or exceeded. INBAND
means the output is active if the weight is within the band value. If trip is OUTBND, the
output is active when the weight is outside of the band value.

BNDVAL

number

The band value for either INBAND or OUTBND trip setpoints. BNDVAL is ignored unless
trip is set to INBAND or OUTBND.

HYSTER

number

Specifies a band around the setpoint value that must be exceeded before the setpoint,
once off, can trip on.

ACCESS

OFF
ON

Front panel access to setpoints. Specify OFF if setpoints will not be tested. ON enables
operator to turn setpoints on/off, change value, or change BANDVAL via front panel entry
during weigh mode.

Setpoint Menu

Parameter

Choices

Description

Table 5-8. Setpoint Menu Parameters (Continued)