Rice Lake CLS-420 Cargo Lift Scale Installation Manual User Manual

Page 37

Advertising
background image

CLS-420 Installation Manual

27

UNITS

LB
KG
OZ
TN
T
G
NONE

Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram, OZ=ounce, TN=short ton; T=metric ton, G=gram

Note: Indicators sold outside North America are configured with KG for both primary and
secondary units

Secondary Units (SECNDR Parameter)

DECPNT

88888.8
888888
888880
8.88888
88.8888
888.888
8888.88

Decimal point location. Determines the location of the decimal point or dummy zeros in
the secondary unit display.

DISPDIV

5D
1D
2D

Display divisions. Selects the value of minimum division size of the displayed weight.

UNITS

KG
OZ
TN
T
G
NONE
LB

Specifies secondary units for displayed and printed weight. Values are: KG=kilogram,
OZ=ounce; TN=short ton; T=metric ton, G=gram; LB=pound

MULT

0.453592
Enter other
choices via
keyboard

Multiplier. Specifies the conversion factor by which the primary units are multiplied to
obtain the secondary units. The default is 0.453592, which is the conversion factor for
changing pounds to kilograms.

Note: Multipliers are pre-configured within the indicator. Manual entry is only necessary
when NONE is selected under UNITS.

To toggle between primary and secondary units, press the UNITS key.

Format Menu

Table 5-3. Format Menu

Advertising