Section 2.12 on, Warning – Rice Lake Digital/Diagnostic - iQube User Manual

Page 17

Advertising
background image

14

iQUBE

Installation Manual

2.12 Installing Tap and Run Connectors for 920i Power

iQUBE

installations that are remotely powered by the

920i

indicator, and those that use the

920i

internal

fiber-optic module, require tap and run connectors to
draw power from the

920i

power supply (see Figures

2-13 and 2-14).

To install tap and run connectors in the

920i

indicator,

do the following:

1. Place red (+6V) wire from

920i

power supply

inside the run channel of the tap and run
connector. The cable tie used to secure the
power supply wires may need to be cut to allow
sufficient slack in the wires.

2. Close side cover of connector until latched.

3. Insert tap wire (+6V supply to

iQUBE

) into

connector. Use inspection port to check wire
position.

4. Use crimping tool to drive u-contact down flush

with top of connector. Close hinged top cover
until latched.

5. Repeat procedure for green (GND) wire tap and

run connector.

6. Use cable ties to secure power supply wires

inside the enclosure.

Figure 2-13.

920i Tap and Run Connector Installation

Figure 2-14.

920i Tap and Run Connector Installation for Internal Fiber-Optic Interface

See Section 2.14.4 on page 16 for more information about installing the

920i

internal fiber-optic interface.

WARNING!

HIGH VOLTAGE

DISCONNECT POWER BEFORE SERVICING

GREEN (GND)

RED (+6V)

POWER SUPPLY

J8

TAP AND RUN
CONNECTORS

GREEN (GND)
RED (+6V)

V2

V1

J4

J3

TAP AND RUN
CONNECTORS

FIBER-OPTIC

INTERFACE

POWER SUPPLY

J8

Advertising