2 downloading to the iqube, 2 using irev, Downloading to the iqube – Rice Lake Digital/Diagnostic - iQube User Manual

Page 33

Advertising
background image

30

iQUBE

Installation Manual

Platforms field. Click the

Platform 1

box to

assign Platform 1 to System 1. Use the
G e n e r a l d i s p l a y t o e n t e r s c a l e s y s t e m
parameters.

4.1.2

Downloading to the iQUBE

Once configuration is complete, you must download
the configuration data from the PC to the

iQUBE

.

1. Go to the Communications menu and select

Connect…

Revolution automatically detects

the

iQUBE

communications port.

2. Return to the Communications menu and

select

Download Configuration

. Click

Begin

to

initiate the download. Downloading may take
up to 30 seconds.

4.2

Using iRev

The

iRev

utility provides a suite of functions used to

support configuration, calibration, customization, and
backup of the

920i

software. Hardware and software

configuration,

920i

display setup for up to ten screen

designs, stream and ticket formatting, setpoint
configuration, database management, and

iRite

program editing are all supported by

iRev

.

Calibration values, scale, setpoint, and display
configuration, database tables, and user programs, can
be both saved and restored to the

920i

using

iRev

. Other

supporting applications provided with

iRev

include:

The

iRev

Editor provides a basic editor and a

compiler for writing

iRite

applications.

The Rice Lake Web Update utility uses your
internet connection to check for and download
updates to the

iRev

and

920i

software.

The iLaunch utility can be installed to display a
set of icons used for convenient startup of

iRev

and its supporting applications, including the
Help system.

Hardware and Software Requirements

M i n i m u m s y s t e m r e q u i r e m e n t s : 1 6 6 M H z ,
x86-compatible, with 32MB RAM (64MB for NT4/
2000), 40MB disk space. Recommended system: 233
MHz, x86-compatible or greater, with 64MB RAM,
40 MB disk space.

iRev

runs on most Windows

®

operating systems,

including Windows 95 (original release), Windows 95
OSR2, Windows 98, Windows 98 SE, Windows ME,
Windows NT 4.0 (SP4 or greater), Windows 2000, and
Windows XP (Home or Professional).

When used with the original release of Windows 95,

iRev

requires an updated version of TAPI. The TAPI

update is included on the

iRev

installation CD and is

available from the RLWS web site at

www.rlws.com

.

Internet Explorer

®

(IE) 4.0 or greater is required to use

the

iRev

help system. Explorer is included on the

iRev

installation CD or is available from Microsoft
Corporation.

iRev

is installed using a standard Windows installation

procedure.

iRev

applications and support files are

installed in a directory named iRev; icons for the

iRev

application, the

iRev

Editor, Uninstall,

and the Rice

Lake Web Update utility are placed in the Windows
Start menu.

See the

920i

Installation Manual for more information

about using

iRev

.

iRev Configuration

Configuration of the

iQUBE

using the

iRev

program is

similar to using the

920i

menus. Use the

Tools

toolbar

selection to configure the serial port used for the

iQUBE

connection.

Figure 4 -2 shows one of the

i Re v

serial port

configuration displays.

Figure 4-2.

iRev Serial Port Configuration Display

Once

iRev

configuration of the

920i

is complete, use

the

Download Configuration

function on the

iRev

Communications menu to download the configuration
to the indicator.

To download the

920i

configuration to the

iQUBE

, use

the

Download

softkey on the

920i

serial port IQUBE

CONFIG menu. Use the

up

and

down

keys to select

Download iQUBE configuration only

, then press

enter

.

At version 2.05 and higher, the

920i

download to

iQUBE

is done automatically after the

iRev

download.